Thin Vertical White Lines/Stripes
All Printers � The toner cartridge is defective or nearly empty. � Gently shake the toner cartridge and reseat. If the error persists, replace the toner cartridge. � � Foreign obstacles are in the path of the laser beam. � Check the laser beam shutter. The printer needs to be cleaned.
5Si/5 � � The focusing lenses in the scanner assembly may be dirty. The beam-to-drum mirror is contaminated.
2686A, 2686D � � � The fuser cleaning pad is dirty. The transfer corona wire is dirty. The laser/scanner assembly is defective.
10
II, IID, III, IIID � � � The transfer corona is dirty or worn. The beam-to-drum mirror is dirty. The laser/scanner assembly is defective.
EN